Location: Home > Products > Flow
SUP-LDG  Electromagnetic flowmeter with Remote Type
  • SUP-LDG  Electromagnetic flowmeter with Remote Type
  • SUP-LDG  Electromagnetic flowmeter with Remote Type
  • SUP-LDG  Electromagnetic flowmeter with Remote Type
  • SUP-LDG  Electromagnetic flowmeter with Remote Type
  • SUP-LDG  Electromagnetic flowmeter with Remote Type
SUP-LDG Electromagnetic flowmeter with Remote Type
Category: Electromagetic flowmeter
Views: 1831
Applications: Electromagnetic flowmeter is only applicable to measure the flow of conductive liquid, which is wide used in water supply, sewage water measuring, industry chemical measuring etc. The remote type is with high IP protection class and can be installed in different locations for the transmitter and converter. Output signal can pulse,4-20mA or with RS485 communication.
Specification


 Product Electromagnetic flowmeter
 Model SUP-LDG
 Diameter Nominal DN10~DN1000
 Nominal Pressure 0.6~4.0MPa
 Accuracy ±0.5%,±2mm/s(flowrate<1m/s)
 Liner material PFA,F46,Neoprene,PTFE,FEP
 Electrode material Stainless steel SUS316, Hastelloy C, Titanium,

 Tantalum Platinum-iridium
 Medium Temperature Integral type: -10℃~120℃

 Split type: -25℃~120℃
 Ambient Temperature -10℃~60℃
 Electrical conductivity Water 20μS/cm other medium 5μS/cm
 Structure type Tegral type, split type
 Protection Class IP65, IP68(optional)
 Product Standard JB/T 9248-1999 Electormagnetic Flowmeter



Introduction


SUP-LDG Remote Type electromagnetic flowmeter is applicable for all conductive liquids, such as water, acids, alkalis, slurries and many others. Typical applications are monitoring accurate measurements in liquid, metering and custody transfer. It can display both instantaneous and cumulative flow, and supports analog output, communication output and relay control functions.

 

    magnetic flowmeter



Application


Electromagnetic flowmeters have been used throughout industries for more than 60 years. These meters are applicable for all conductive liquids, such as:

Domestic water, industrial water, raw water, ground water, urban sewage, industrial wastewater, the processed neutral pulp, pulp slurry, etc


magnetic flowmeter use


Selet lining


Lining materialMain PerformanceApplications
Teflon1.The most steady material in plastics which is resistibal to boiling hydrochloric 
acid,vitriolandqua fortis as well as strong alkali and organic impregnates.        
2.Not be perfect in abrasion resistance.
Strong corrosive mediums such 
as strong acid and alkali
PFAHaving the same abrasion resistance with PTFE.
Having strong ability of load pressure resistance.
Applicable in state of load pressure
F461.Have the same abrasion resistance with PTFE.
2.Resistable for low abrasion.
3.Having strong resistance to load pressure.
  1.The same as PTFE.2.Applicable 
in mediums of low abrasion.
 Neoprene 1.Be of good elasticity,retractility and abrasion resistance.
2.Be resistant to low aicd,alkali and salt but not for oxidation mediums.
Water,sewage and slurry,mineral 
serosity of low abrasion.
Polyurethane1.Be of good abrasion resistibility.
2.Not be perfect in acid/alkali resisitance.
3.Can't be used for water mixed with organic impregnants.
Applicable in mineral serosity,slurry 
and coal slurry of high abrasion


Selet electrode


Electrode materialApplications
Stainless steel SUS316Applicable in water,sewage and corrosive mediums.Widely used in industries of petrol,
chemistry,carbamide,etc
Stainless steel
covered with tungsten carbide
Applicable in mediums of no corrosive and low abrasion.
  Hastelloy B(HB)Having strong resistance to hydrochloric acid of any consistance which is below bioling 
piont. Also resistable against vitriol,phosphate,hydrofluoricacid,organic acid etc which 
are oxidable  acid,alkali and non-oxidable salt.
Hastelloy C(HC)Be resistant to oxidable acid such as nitric acid,mixed acid as well as oxidable salt such as
 Fe+++,Cu++and sea water
TitaniumApplicable in seawater,and kinds of chloride,hypochlorite salt,oxidable acid(including
fuming  nitric acid),organic acid,alkali etc.Not resistant to a pure reducing acid(such as 
sulphuric acid,hydrochloric acid)corrosion.But if acid contains antioxidant(such as 
Fe+++,Cu++)is greatly  reduce corrosion.
DaIn addition to hydrofluoric acid, fuming sulfuric acid, alkali remaining outside chemicals, 
including boiling hydrochloric acid
Platinum-iridiumAlmost be applicable in all chemical mediums except for aqua fortis,ammonium salt.



More about Supmea


A-supmea-automation.jpg


China flowmeter supplier

China flow meter supplier

Flowmeter manufacturer


Cooperation


Supmea cooperation with well-known automation manufacturers E+H and Jumo!

cooperation with E+H

cooperation with E+H and jumo


Supmea exhibition



supmea Exhibition  Electromagnetic Flow Meter

supmea exhibition Electromagnetic Flow Meter

· 2019 Supmea Exhibition Preview

  

TimeExhibitionAddress
  10 – 12 Mar 2019  SPS –Industrial Automation Fair 2019  Guangdong, China
  12 - 15 Mar 2019  HARFKO 2019  Seoul, Korea
  20 - 22 Mar 2019

  Water Philippines 2019

  Manila, Philippines
  27 - 29 Mar 2019  Automation World 2019  Seoul, Korea
  1 - 5 Apr 2019  Hannove Messe 2019  Hannover, Germany
  3 - 5 Jun 2019  Aquatech China 2019Shanghai, China
  July 2019  World Sensors Summit 2019

  Henan, China

  17 - 19 Jul 2019  IndoWater 2019Jakarta, Indonesia
  18 - 20 Sep 2019  IE-expo 2019  Guangdong, China
  2 - 5 Oct 2019   ISK-SODEX Istanbul 2019Istanbul, Turkey
  20 - 23 Oct 2019   WETEX 2019Dubai, UAE
  6 - 8 Nov 2019  VIETWATER 2019  Ho Chi Minh, Vietnam
 25 - 27 Nov 2019   MICONEX 2019  Beijing, China


               Contact us : info@supmea.com   /   0086-15158063876(Whatsapp)                  


Copyright@Supmea Automation
Address:5th floor, Building 4, Singapore Hangzhou Science & Technology Park, Hangzhou, China
Email: info@supmea.com
Follow us on :
  • *NAME:
  • *SELECT PRODUCT TYPE:
  • *EMAIL:
  • PHONE NUMBER: