SUP-LDG  Electromagnetic flowmeter with Remote Type
  • SUP-LDG  Electromagnetic flowmeter with Remote Type
  • SUP-LDG  Electromagnetic flowmeter with Remote Type
  • SUP-LDG  Electromagnetic flowmeter with Remote Type
  • SUP-LDG  Electromagnetic flowmeter with Remote Type
SUP-LDG Electromagnetic flowmeter with Remote Type
Category: Electromagetic flowmeter
Views: 833
Applications: Electromagnetic flowmeter is only applicable to measure the flow of conductive liquid, which is wide used in water supply, sewage water measuring, industry chemical measuring etc. The remote type is with high IP protection class and can be installed in different locations for the transmitter and converter. Output signal can pulse,4-20mA or with RS485 communication.
Specification

Flowmeter Product Features.jpg

SUP-LDG Remote Type electromagnetic flowmeter is applicable for all conductive liquids, such as water, acids, alkalis, slurries and many others. Typical applications are monitoring accurate measurements in liquid, metering and custody transfer. It can display both instantaneous and cumulative flow, and supports analog output, communication output and relay control functions.

 

    Electromagnetic flow meter.png


Electromagnetic Flow Meter Product Parameters .jpg

Electromagnetic Flow Meter Technical Performance Parameters
Diameter NominalDN10 ~ DN1000
Nominal Pressure0.6~4.0MPa(special pressure can be made to)
Accuracy±0.5 %, ±2mm/s (flowrate < 1m/s)
Liner materialPFA,F46,Neoprene,PTFE, FEP
Electrode materialStainless steel SUS316, Hastelloy C, Titanium, Tantalum Platinum-iridium
Medium TemperatureIntegral type-10°C~+80°C
Split type-25 – 180℃
Ambient Temperature-10℃~60℃
Medium Electrical conductivitywater 20μS/cm other medium 5μS/cm
Structure type Integral type, split type
Protection ClassIP65,IP68(optional)
Product StandardJB/T 9248-1999 Electormagnetic Flowmeter


Electromagnetic Flow Meter


choose Electromagnetic Flow Meter lining.jpg

Lining materialMain PerformanceApplications
Teflon1.The most steady material in plastics which is resistibal to boiling hydrochloric 
acid,vitriolandqua fortis as well as strong alkali and organic impregnates.        
2.Not be perfect in abrasion resistance.
Strong corrosive mediums such 
as strong acid and alkali
PFAHaving the same abrasion resistance with PTFE.
Having strong ability of load pressure resistance.
Applicable in state of load pressure
F461.Have the same abrasion resistance with PTFE.
2.Resistable for low abrasion.
3.Having strong resistance to load pressure.
  1.The same as PTFE.2.Applicable 
in mediums of low abrasion.
 Neoprene 1.Be of good elasticity,retractility and abrasion resistance.
2.Be resistant to low aicd,alkali and salt but not for oxidation mediums.
Water,sewage and slurry,mineral 
serosity of low abrasion.
Polyurethane1.Be of good abrasion resistibility.
2.Not be perfect in acid/alkali resisitance.
3.Can't be used for water mixed with organic impregnants.
Applicable in mineral serosity,slurry 
and coal slurry of high abrasion


select Electromagnetic Flow Meter electrode .jpg


Electrode materialApplications
Stainless steel SUS316Applicable in water,sewage and corrosive mediums.Widely used in industries of petrol,
chemistry,carbamide,etc
Stainless steel
covered with tungsten carbide
Applicable in mediums of no corrosive and low abrasion.
  Hastelloy B(HB)Having strong resistance to hydrochloric acid of any consistance which is below bioling 
piont. Also resistable against vitriol,phosphate,hydrofluoricacid,organic acid etc which 
are oxidable  acid,alkali and non-oxidable salt.
Hastelloy C(HC)Be resistant to oxidable acid such as nitric acid,mixed acid as well as oxidable salt such as
 Fe+++,Cu++and sea water
TitaniumApplicable in seawater,and kinds of chloride,hypochlorite salt,oxidable acid(including
fuming  nitric acid),organic acid,alkali etc.Not resistant to a pure reducing acid(such as 
sulphuric acid,hydrochloric acid)corrosion.But if acid contains antioxidant(such as 
Fe+++,Cu++)is greatly  reduce corrosion.
DaIn addition to hydrofluoric acid, fuming sulfuric acid, alkali remaining outside chemicals, 
including boiling hydrochloric acid
Platinum-iridiumAlmost be applicable in all chemical mediums except for aqua fortis,ammonium salt.




supmea automation flowmeter supplier

Supmea flowmeter supplier

CHINA flowmeter factory

China flowmeter supplier

China flow meter supplier

Flowmeter manufacturer


cooperation with E+H

Supmea cooperation with well-known automation manufacturers E+H and Jumo!

cooperation with E+H

cooperation with E+H and jumo



Electromagnetic Flow Meter supmea exhibition

supmea Exhibition  Electromagnetic Flow Meter

supmea exhibition Electromagnetic Flow Meter

· 2018 Supmea Exhibition Preview


ExhibitionAddressTime
 SRW India Water  Chennai, India January  4-6,  2018
 Water Expo 2018 Chennai, India February 8-10, 2018
 GD Water 2018 Guangzhou, China April      2-4,  2018
 ASIA WATER 2018 Kuala Lumpur, Malaysia April    10-12,2018
 HANNOVER MESSE 2018 Hannover, Germany April    23-27,2018
 IE expo 2018 Shanghai, China May      3-5,  2018
 AQUATECH CHINA 2018 Shanghai, China May 31-June 2, 2018
 Singapore International Water Week Singapore July      9-11, 2018
 Automation India Expo 2018 Mumbai,India August 29-September 1,2018
 Industrial Automation North America Chicago, USA September 10-15, 2018
 Pak Water & Energy Expo 2018 Lahore, Pakistan October 24-25, 2018
 MICONEX 2018 Beijing, China October 24-27, 2018
 VIET WATER 2018 Ho Chi Minh, Vietnam November 7-9, 2018


               Contact us : info@supmea.com   /   0086-15158063876(Whatsapp)                  


supmea automation Electromagnetic Flow Meter


Copyright@Supmea Automation
Address:No.600,No.21 Street, Hangzhou Economic&Technological Development Area, Hangzhou,China
Email: info@supmea.com
Follow us on :
  • *NAME:
  • *SELECT PRODUCT TYPE:
  • *EMAIL:
  • PHONE NUMBER:
  • *COMMENTS: