Location: Home > Products > Signal Conditioners
SUP-825-J Signal Calibrator High accuracy
  • SUP-825-J Signal Calibrator High accuracy
  • SUP-825-J Signal Calibrator High accuracy
  • SUP-825-J Signal Calibrator High accuracy
  • SUP-825-J Signal Calibrator High accuracy
SUP-825-J Signal Calibrator High accuracy
Category: Signal calibrator
Views: 1949
Applications: Applications: Signal generator has a multiple signal Output and measurement including voltage, current and thermoelectric couple with LCD screen and silicone keypad, simple operation, longer standby time, higher accuracy and programmable output. It’s widely used in LAB Industrial field, PLC Process Instrument, Electric value and other area’s debugging.
Specification

General Specifications

Operating temperature

-10~55

Storage temperature

-20~70

Relative Humidity (RH operating without condensation)

90%(10~30)

75%(30~40)

45%(40~50)

35%(50~55)

Uncontrolled<10

EMC

EN55022, EN55024

Vibration

Random, 2g, 5 to 500Hz

Concussion

30g, 11ms, half sine bow wave

Power requirement

4 AA Ni-MH, Ni-Cd batteries

Size

215mm×109mm×44.5mm

Weight

About 500g

 

 

 DC Voltage

 Range

Accuracy

 Measurement

 (0~100)mVDC(Upper display)

 ±0.02%

 (0~30)VDC(Upper display)

 ±0.02%

 (0~100)mVDC(Lower display)

 ±0.02%

 (0~20)VDC(Lower display)

 ±0.02%

 Source

 (0~100)mVDC

 ±0.02%

 (0~10)VDC

 ±0.02%

 

 


Resistance

Range

Accuracy

4-wire

2-, 3-wire

Accuracy

Accuracy

Measurement

(0~400)Ω

±0.1Ω

±0.15Ω

(0.4~1.5)kΩ

±0.5Ω

±1.0Ω

(1.5~3.2)kΩ

±1.0Ω

±1.5Ω

Excitation Current:0.5mA

Clear of resistance before measuring according to ‘10.4 Clear of Resistance and RTDs’.

*3-wire: Assumes matched leads with a total resistance not exceeding 100Ω.

Resolution (0~1000)Ω:  0.01Ω;

(1.0~3.2)kΩ: 0.1Ω.

 




Introduction

Signal Calibrator


Advantages


· Two separate channels display.

  the upper display shows measure parameters ; 

  the lower one shows measure or source parameters;

· Counting pulse function

· Calibration functions

· Auto ramping and auto stepping

· Manual and automatic cold junction compensating

· Clear function

· Temperature unit switching

· Auto flashing jacks

· Backlight LCD

· Battery gauge



Source

Range

Excitation Current from Measurement Device

Accuracy

(15~400)Ω

(0.15~0.5)mA

±0.15Ω

(15~400)Ω

(0.5~3)mA

±0.1Ω

(0.4~1.5)kΩ

(0.05~0.8)mA

±0.5Ω

(1.5~3.2)kΩ

(0.05~0.4)mA

±1.0Ω

Clear of resistance before sourcing according to ‘10.4 Clear of Resistance and RTDs.

 

 

Frequency

Range

Accuracy

Measurement

(1~1100)Hz

±0.05%

(1.0~10.0)kHz

±0.05%

Sensitivity: Not less than 1V (peak- peak)

Wave form: Square wave

Source

(1~1100)Hz

±0.05%

(1.0~5.0)kHz

±0.05%

Wave form: (0~8)V (peak-peak)

Load drive capability: 3mA

 

Type

Range(℃)

Accuracy

Measure  

 4-wire()

Measure

2-,3-

(℃)

Output

()

Cu50

-50~150)℃

±1.2

±2.0

±1.2

Pt100(385)

-200~800)℃

±0.6

±1.0

±0.6

Resolution: 0.1

Excitation Current (Source):

Cu50, Pt100(385), Pt100(3916), Pt200(385): (0.15~3.0)mA;

Pt500(385): (0.05~0.80)mA; Pt1000(385): (0.05~0.40)mA.

Clear of RTD before measuring or sourcing according to ‘10.4 Clear of Resistance and RTDs.

*3-wire: Assumes matched leads with a total resistance not exceeding 100Ω.

 

 DC Current

 Range

 Accuracy

 

 Measurement

 (0~24)mADC

±0.02%

 

 Source

 (0~24)mADC

±0.02%


Thermocouple (TC)

Type

Range

 

Measure and Source Accuracy

(When Cold Junction temperature is 0)


J

(-200~0)

±0.8

(0~1200)

±0.5

K

(-200~0)

±1.0

(0~1370)

±0.6

T

(-200~0)

±1.0

(0~400)

±0.6

E

(-100~0)

±0.7

(0~950)

±0.5

R

(-20~0)

±2.3

(0~500)

±1.6

(500~1750)

±1.2

S

(-20~0)

±2.3

(0~500)

±1.6

(500~1750)

±1.3

B

(600~800)

±2.0

(800~1000)

±1.6

(1000~1800)

±1.2

N

(-200~0)

±1.3

(0~1300)

±0.7

Resolution :

J, K, T, E, N: 0.1℃

B, R, S:  1

Cold junction error: ±0.5, does not including sensor error.


More about Supmea

supmea automation

steam flowmeter


Cooperation


Supmea cooperation with well-known automation manufacturers E+H and Jumo!

cooperation with E+H

cooperation with E+H and jumo



· 2019 Supmea Exhibition Preview


  

TimeExhibitionAddress
  10 – 12 Mar 2019  SPS –Industrial Automation Fair 2019  Guangdong, China
  12 - 15 Mar 2019  HARFKO 2019  Seoul, Korea
  20 - 22 Mar 2019

  Water Philippines 2019

  Manila, Philippines
  27 - 29 Mar 2019  Automation World 2019  Seoul, Korea
  1 - 5 Apr 2019  Hannove Messe 2019  Hannover, Germany
  3 - 5 Jun 2019  Aquatech China 2019Shanghai, China
  July 2019  World Sensors Summit 2019

  Henan, China

  17 - 19 Jul 2019  IndoWater 2019Jakarta, Indonesia
  18 - 20 Sep 2019  IE-expo 2019  Guangdong, China
  2 - 5 Oct 2019   ISK-SODEX Istanbul 2019Istanbul, Turkey
  20 - 23 Oct 2019   WETEX 2019Dubai, UAE
  6 - 8 Nov 2019  VIETWATER 2019  Ho Chi Minh, Vietnam
 25 - 27 Nov 2019   MICONEX 2019  Beijing, China


          Contact us, to get more information: info@supmea.com   /   0086-15158063876             


Supmea automation.jpg


Copyright@Supmea Automation
Address:5th floor, Building 4, Singapore Hangzhou Science & Technology Park, Hangzhou, China
Email: info@supmea.com
Follow us on :
  • *Name:
  • *Select product:
  • *Email:
  • Phone number:
  • *Comments: